| B) Typical Sizing Formula: |
Vr = 14.7t(Qr-Qc)
—————
Pmax – Pmin
Where:
t = time (min) that receiver can supply required amount of air,
Qr = consumption rate of pneumatice system (cfm),
Qc = output flow rate of compressor (cfm),
Pmax = maximum pressure level in reciever (psi),
Pmin = minimum presssure level in receiver (psi),
Vr = reciever size (ft3) |